CA 6115 Installation Testers
Inside its worksite case, the CA 6115 is a compact electrical installation tester for taking all measurements to comply with NF C15-100.
Large, backlit LCD display.
Powered by a rechargeable Ni / MH battery. It has a memory capable of storing 800 measurements, as well as an RS 232 interface.
For measuring insulation, RCDs, earth, loop, continuity, phase sequence and current and current leakage measurements using a clamp.
For testing and certifying installations according to NF C 15-100.
DownloadUser manual power quality analyser c a 8334 chauvin arnoux. Free Download e-Books Use this program to illustrate your book, your website or to make custom coloring pages for your kids. User manual power quality analyser c a 8334 chauvin arnoux Download User manual power quality analyser c a 8334 chauvin arnoux. Chauvin Arnoux CA6550 Digital Megohmmeter Details. Chauvin Arnoux's CA6500 range of megohmmeters are purpose-built for testing on high voltage applications such as transformers, cables, rotating machinery and more. Allowing it to store and download a significant amount of testing data. Chauvin Arnoux CA6550 Digital Megohmmeter Key Features. 01 mA / 1% 400mA / 4mA / 40mA / 400mA / 10A / 20A 0.01 mA / 0.39%. Dual (2 parametri afiºaþi simultan).001 Hz / 0.01 W / 0.MULTIMETRE DIGITALE PROFESIONALE CHAUVIN ARNOUX CA 5289 Mod de lucru CA 5287 DMM 240 manual ºi automat iluminat.01 mV / 0.
Voltage range: | 5 → 440 Vac and Vdc ±1 % |
Current range: | 4 mA → 300 A (with clamp) ±2% |
Frequency range: | 15.3 Hz → 450 Hz ±0.1% |
Insulation (IEC 61557-2): | |
Nominal voltage: | 100 - 250 - 500 VDC |
Range: | 0.05 → 300 MΩ / 600 MΩ ±6% |
Nominal current: | >1 mA |
Earth (IEC 61557-5): | |
Supply: | 95 → 145 Vac / 175 → 300 Vac |
Frequency: | 15.3 → 17.5 Hz / 45 → 65 Hz |
Range: | 0.15 Ω → 10 kΩ ±10% |
Continuity (IEC 61557-4): | |
Test voltage: | 18 Vdc |
Nominal current: | > 200 mA up to 10 W |
Range: | 0.12 Ω → 2 kΩ ±5% |
Loop (IEC 61557-3): | |
Supply: | 95 → 145 Vac / 175 → 300 Vac 330 → 440 Vac |
Frequency: | 15.3 → 17.5 Hz / 45 → 65 Hz |
Range: | 0.12 Ω → 200 Ω ±10% |
Short-circuit current calculation: | 2 A → 30 kA |
RCD (IEC 61557-6): | |
Supply: | 95 → 145 Vac / 175 → 300 Vac |
Frequency: | 15.3 → 17.5 Hz / 45 → 65 Hz |
Rating: | 10 - 30 - 100 - 300 - 500 mA or 6 → 1000 mA (steps of 1 mA) |
Test: | IN / 2, IN, 2IN, 5IN or, ramp from 0.5 → 1.05 IN |
Phase sequence (IEC 61557-7): | |
Supply: | 20 → 440 Vac |
Frequency: | 15.3 → 420 Hz |
Dimensions (mm): | 295 x 230 x 108 |
Weight: | 2100 g |
Standards
IEC 1010-1 Cat. III - 300 V
Attribute | Value |
---|---|
Tester Type | Insulation & Continuity Tester |
Minimum Test Voltage | 100V |
Maximum Test Voltage | 500V |
Maximum Insulation Resistance Measurement | 600MΩ |
Display Type | LCD |
Test Current | 200mA |
Minimum Operating Temperature | -10°C |
Maximum Operating Temperature | +55°C |
Power Source | Battery |
Safety Category Level | CAT III |
Safety Category Voltage | 300V |
Safety Category | CAT III 300 V |
Battery Type | Rechargeable NiMH |
Length | 295mm |
Model Number p | C.A 6115 |
Width | 230mm |
Weight | 2.1kg |
Height | 108mm |
Dimensions | 295 x 230 x 108mm |
CA8334 Power Quality Analyser
Designed for energy supply departments and electrical maintenance services in industrial and administrative buildings, the QualiSTAR 3 Power Quality analyser combines the functionality of a powerful troubleshooting test meter with true power quality meter features.
Includes an oscilloscope and data logger
Easy to use menu driven unit
Rugged handheld unit gives the user a clear visual display of all voltage and current waveforms, which include a vector diagram of imbalance on each of the phase voltages
Fast identification of power quality problems, including harmonics - up to the 50th Order, flicker, interruptions - with adjustable thresholds, dips and frequency
Power/energy mode provided full monitoring of such parameters as W, Var, VA, Wh, Warh, Wah, PF and DPF
Carry case for 'hands free’ operation (included)
4MB of memory, allows assessment of voltage quality parameters according to EN50160 and the recording of voltage and current, power and flicker to identify intermittent problems chart and multi parameters display
50 transients can be captured, each at the sampling rate 12.8kHz, storage of 4 periods of time waveform are displayed with 256 counts per period
The Alarm Mode provides a trigger on different thresholds for any chosen parameter
Collected data can be analysed directly within the QualiSTAR
Data and captured “screen shots” can be downloaded via the optical RS-232 to the QualistarView Window software (provided) for detailed analysis
12 coloured screenshots can be stored and printed directly from a suitable serial printer
Supplied with a 3800mAh NiMH rechargeable battery. The unit may also be mains powered for continuous use whilst charging
Complies with IEC 61010-1, 600V CATIV, pollution degree 2
Choice of AC current sensors pack available separately to suit most applications
Ampflex clamps: Set of 3 reading from 10 to 3000Aac (10Hz to 100Hz) 140mm dia.
MN93 clamps: Set of 3 reading from 2 to 240Aac (48 to 65Hz) 20mm dia.
Selectable scaling for other AC current transformer inputs is provided
Principal values computed:
Neutral current
Crest factors for current and voltage
K factors for current (transformer application)
Power factor, displacement factor and tangent
Short-term voltage flicker
Voltage and current unbalance
Total harmonic distortion
Average, min and max values of any computed value
Nonton streaming drama korea jang ok jung sub indonesia. Title: 장옥정 / Jang Ok Jung Chinese Title: 張玉貞 Previous Known as: 장옥정, 사랑에 살다 / Jang Ok Jung, Live in Love Genre: Period, Romance, Melodrama Episodes: 24 Broadcast network: SBS Broadcast period: 2013-Apr-08 to 2013-June-25 Air time: Monday & Tuesday 21:55 Synopsis This drama tells the story of Jang Hee Bin (), one of the most famous royal concubines in the Joseon Dynasty who was behind the deposition of King Sook Jong’s () wife, Queen In Hyun ().
Safety | EN IEC 61010 |
Power Measurements | 0 to 9999KW (Active); 0 to 9999KVAR (Reactive); 0 to 9999KVA (Apparent) |
Power Resolution | 4 digits |
Memory (Test results) | Yes |
Power Factor | -1 to +1 |
Resolution ac Current | 0.1A (if >1000 A, rms); 1 A (if >1000 A, rms) |
Accuracy ac Current | ±(0.5% +0.2 A) (rms) |
Resolution dc Current | 0.1A (if >1000 A, rms); 1 A (if >1000 A, rms) |
Accuracy dc Current | ±( (0.5% +0.2A) (rms) |
Maximum ac Voltage | 480Vrms (Single Phase); 800 Vrms (Phase - Phase) |
Resolution ac Voltage | 0.1V (rms) |
Accuracy ac Voltage (V, mV) | ±( (0.5% +0.5V) (rms) |
Maximum dc Voltage | 480 Vrms (Single Phase); 800 Vrms (Phase - Phase) |
Accuracy dc Voltage (mV, V, Percent) | ±( (0.5% +0.5V) (rms) |
Size (HxWxD) and Weight | 240 x 180 x 55mm, 1.5g |
Chauvin Arnoux Ca 6115n Manual: software, free download 2017
Note
Calibration certificate contains measurements made using unity power factor only.
Car modeling tutorial. Which allow you to model a complex car. To start this model you will need some schematics or blueprints of vehicle in question, in our case, the Land Rover Freelander. Here is how to get your images into 3ds max and ready to use. Open your favourite image editor and cut your blueprints into four pieces: top, side.
Supplied with
QualistarView software, DB9F optical RS-232 lead, 4 off 3m leads fitted with 4mm plugs, 4 crocodile clips, 1 mains lead, 1 user’s manual, 1 soft carry case.
Chauvin Arnoux Ca 6115n Manual: software, free download Pc
Chauvin Arnoux Ca 6115n Manual Software free. download full Version
Attribute | Value |
---|---|
Absolute Maximum Power Measurement | 9999kW |
Number of Phases | 3 |
Maximum Voltage | 600V |
Best Voltage Measurement Accuracy | ±0.5 % |
Best Current Measurement Accuracy | ±0.5 % |
Calibrated | SYSCAL |
Display Type | LCD |
Measurement Type | Energy, Frequency, Harmonics, Peak Current, Peak Voltage, TRMS Current, TRMS Voltage |
Measurement Standards | EN50160 |
Interface Type | RS232 |
Memory Capacity | 4MB |
Power Source | Battery |
Battery Type | Rechargeable NiMH |
Height | 55mm |
Weight | 1.5kg |
Minimum Operating Temperature | 0°C |
Maximum Operating Temperature | +50°C |
Minimum Frequency | 40 Hz |
Maximum Frequency | 70Hz |
Dimensions | 180 x 240 x 55mm |
Model Number p | C.A 8334 |
Length | 180mm |
Width | 240mm |